Ion-exchange resin

Calculate media volume

Select the tank size


Volume of loading, liters Quantity of loading, bags

Purpose

This media is used in food industry, for preparation of drinking water, in heating systems, as well as for softening water for boilers and steam generators, where a complete lack of hardness ions is required.

Description

A filter material represents ion-exchange resin (cationite) in the Na+ form, gel structure with styrene-divinyl benzene matrix and strongly acidic functional groups (sulpho-groups). It has a high level of chemical and osmotic stability. Owing to special production technology, it contains the minimum amount of mineral and organic impurities.

Equivalents

The equivalents are such cation exchange resins as KU-2-8, Amberlite IR 120, Purolite C 100, Lewatit C 249 / 267 / S100G1.

The requirements for raw water

No special requirements are made, but before treating with ion-exchange resins, the water should undergo mechanical cleaning from coarse particles.

The maximum working temperature 120 ˚С
Working range of pH 0 - 14 pH

Commissioning and operation

After loading Beta Soft into the tank, it should be washed with raw water in the amount of five volumes of resin (e.g. 25 l of resin is required for 0844 casing, consequently, the washing water volume should be 25*5 = 125 l). The regeneration is carried out with the sodium chloride solution and may be both direct-flow and back-flow.

Standard working conditions for direct-flow regeneration

Stage Instructions Duration or quantity of water
Backwash To be performed at the minimum temperature with the bed expansion of 50-80% 1 free volume for pure water supply or 2-3 free volumes if mechanical impurities are present
Bed precipitation Wait until the bed is completely formed 3-8 minutes
NaCl supply 50-250 g/l should be applied as 10% brine with supplying 2-4 volumes of resin/h Usually, 20-45 minutes depending on the concentration and flow
Slow washing Water in a quantity of 1-3 resin volumes with the supply being approximately equal to regenerate supply Usually, 20-45 minutes depending on the water volume and flow
Final washing Water in a quantity of 3-6 resin volumes preferably at the working flow or > 15 resin volumes /h Usually, 10-20 minutes

Standard working conditions for counter-flow regeneration

Stage Instructions Duration or quantity of water
NaCl supply 50-150 g/l should be applied as 10% brine with supplying 24 volumes of resin/h Usually, 20-45 minutes depending on the concentration and flow
Slow washing Water in a quantity of 1-2 resin volumes with the supply being approximately equal to regenerate supply Usually, 20-45 minutes depending on the water volume and flow
Final washing Water in quantity of 2-4 resin volumes preferably at the working flow or > 15 resin volumes /h Usually, 10-20 minutes

Equivalents

Specifications

  • Beads diameter (monosphere) 0,315 ÷ 1,25 mm
  • Uniformity Coefficient max. 1.6
  • Moisture content 55 – 65 %
  • Osmotic stability min. 96 %
  • Full static exchange capacity min. 1,9 mmol/см3 (mg-eq./cm3)
  • Bulk weight 0,720 ÷ 0,750 g/cm3
  • True density 1,25 ÷ 1,29 g/cm3
  • Package size 25 l
  • Working water flow 8 – 42 resin volumes/h